Critical Radiant Flux Carpet
Rubber flooring indent only.
Critical radiant flux carpet. Astm e648 10 critical radiant flux new york 20. It provides a basis for estimating one aspect of fire exposure behavior for floor covering systems. Euroflor arkitek carpet tiles. 1 2 this fire test response standard measures the critical radiant flux at flame out.
Critical radiant flux tested to iso 9239 1. The carpet it just feels better campaign is an initiative of the carpet institute of australia. The imposed radiant flux simulates the thermal radiation levels likely to impinge on the floors of a building whose upper surfaces are heated by flames or hot gases or both from a fully developed fire in an. The fire test iso 9239 1 is only for floor coverings not wall coverings.
Euroflor paddington carpet tiles. Standard test method for critical radiant flux of floor covering systems using a radiant heat energy source. 16 hugo johnston drive penrose auckland auckland 09 444 3234 wellington 04 569 9599. The critical radiant heat flux is basically the lowest energy a fire requires to keep burning hence the higher the value the better.
Critical radiant flux testing pdf. Critical radiant flux crf and smoke development rate a floor covering is required to have critical radiant flux crf greater than specified values dependent on building type location within the building and whether or not a sprinkler system is. N the heat energy measured at the point of extinction is the critical heat flux chf also called the critical radiant flux crf in the building code of australia. Fire test reports for a range of timber floor coverings are available here.
Carpet production as well as retailers and suppliers of goods and services to the industry. Scope purpose of test to measure the ability of a flooring material categorized as interior floor finish to limit the progression of a fire through a corridor. To comply with the code a building needs to be matched to a risk group which is paired with an acceptable solution. But when a carpet manufacturer tests carpet to determine crf data the carpet and substrate used e g.
N smoke is measured over the duration of the test. Astm e648 10 critical radiant flux single specimen. Astm e648 10 critical radiant flux non carpet specimen 200. Astm e648 10 critical radiant flux.
Plywood or particleboard should be nominated as part of the test. The new code in 2012 introduced a different fire test method for floor coverings. Critical radiant flux crf and smoke development rate. 1 1 2 this fire test response standard measures the critical radiant flux at flameout and provides a basis for estimating one.
Astm e648 10 critical radiant flux over pad 200.